PM-8000 multi-functional protable ecg patient monitor
mobile ecg instructionsIt is a kind of multi-functional mini patient monitor. It integrates the functions of auscultation,ECG collection,SpO2 and PR inspection.
The product is applicable for family, hospital, private clinique, community medical treatment.etc.
mobile ecg main features1.Compact and portable,easy to use2.Display of ECG waveform, heart rate,SpO2 ,pulse rate ,pulse waveform 3.Earphone output and 16 steps volume adjustable4.Alarm for SpO2 and pulse rate exceeding limits5.Real-time detecting, TF card data record and review6.Real-time clock7.Recorded data can be transferred to a PC8.PC analysis software9.Low power consumption
Display : 2.4" color LCD Power consumption:≤120mAVoltage:DC 3.6 ~ 4.2VPower Supply: 3.7V Lithium Battery Battery working hour:It can last more than 7 hours when the power is full.Safety Type: Internally powered equipment, B Type
mobile ecg accessoriesAn User ManualAn earphone, it is stethoscope
A power adapter, lithium battery charger
A USB date line
An oximeter probe
ecg cables
Built-in single guide league electrode
A CD, to analyze and install software
mobile ecg main parametersHeart Rate measuring range: 30bpm~300bpm ,Accuracy: ±2 bpm or ±2%(select larger)SpO2 measuring range: 0%~100% (the resolution is 1%),Accuracy: 70% ~100% :±2% ,below 70% unspecifiedPulse Rate measuring range: 30bpm~250bpm,Accuracy: ±2 bpm or ±2%(select larger)Resistance to surrounding light: The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1%.Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown orrectly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ±2 bpm or ±2% (select larger).Stethoscope(electronic sensor ,three Stethoscope modes),Heart:20~230Hz,Lung:100~800Hz,H&L:20~800Hz
PM-8000 multi-functional protable ecg patient monitor