Zhuhai Joyful Technology Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Zhao Li
  • Company Name : Zhuhai Joyful Technology Co., Ltd.
  • Tel : 86-20-62358196
  • Fax : 86-20-34258943
  • Address : Guangdong,Zhuhai,4041 Fourth Floor west side, No.1238 Jiuzhou Road East, Jida, Zhuhai.
  • Country/Region : China
  • Zip : 519000

multi-functional mini patient monitor mobile ecg Language Option French

multi-functional mini patient monitor mobile ecg Language Option French
Product Detailed
mobile ecg 1.wireless home mobile ecg. 2.continuous running time:7 hours. 3.ecg LCD display: 2.4" TFT, 320

mobile ecg instructionsIt is a kind of multi-functional mini patient monitor. It integrates the functions of auscultation,ECG collection,SpO2 and PR inspection.

The product is applicable for family, hospital, private clinique, community medical treatment.etc.

mobile ecg main features1.Compact and portable,easy to use2.Display of ECG waveform, heart rate,SpO2 ,pulse rate ,pulse waveform 3.Earphone output and 16 steps volume adjustable4.Alarm for SpO2 and pulse rate exceeding limits5.Real-time detecting, TF card data record and review6.Real-time clock7.Recorded data can be transferred to a PC8.PC analysis software9.Low power consumption

Display : 2.4" color LCD Power consumption:≤120mAVoltage:DC 3.6 ~ 4.2VPower Supply: 3.7V Lithium Battery   Battery working hour:It can last more than 7 hours when the power is full.Safety Type: Internally powered equipment, B Type

mobile ecg accessoriesAn User ManualAn earphone, it is stethoscope

 A power adapter, lithium battery charger

A USB date line

An oximeter probe

ecg cables

Built-in single guide league electrode

A CD, to analyze and install software

mobile ecg main parametersHeart Rate measuring range: 30bpm~300bpm ,Accuracy: ±2 bpm or ±2%(select larger)SpO2 measuring range: 0%~100% (the resolution is 1%),Accuracy: 70% ~100% :±2% ,below 70% unspecifiedPulse Rate measuring range: 30bpm~250bpm,Accuracy: ±2 bpm or ±2%(select larger)Resistance to surrounding light: The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1%.Measurement Performance in Weak Filling Condition: SpO2 and pulse rate  can  be shown orrectly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ±2 bpm or ±2% (select larger).Stethoscope(electronic sensor ,three Stethoscope modes),Heart:20~230Hz,Lung:100~800Hz,H&L:20~800Hz 

multi-functional mini patient monitor mobile ecg Language Option French



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.